home *** CD-ROM | disk | FTP | other *** search
/ macdrivermuseum.net / www.macdrivermuseum.net.tar / www.macdrivermuseum.net / nic / daynaccard121.sit / communicard installer 1.2.1 mac / CommuniCard Installer 1.2.1 / CommuniCard Appendix C < prev    next >
Text File  |  1996-10-23  |  24KB  |  640 lines

  1. Appendix C AT Command Set 
  2.  
  3. This appendix includes AT Command reference tables for your CommuniCard modem. Find the AT Command tables that relate to your particular modem (i.e. cellular or non-cellular).
  4.  
  5. AT Commands for Cellular-Ready Modems Syntax: AT__n For example, command &Sn becomes AT&S0 or AT&S1.
  6.  
  7. Basic Modem Commands This table contains an alphabetical list of basic modem commands.
  8.  
  9. Command          Definition
  10. =               Write last accessed S register (AT=nnn)
  11. ?               Read last accessed S register (AT?)
  12. A/              Repeat last command, no 'AT' precedes this command
  13. A               Go off-hook in ANSWER mode
  14. B, B0           CCITT V.22 mode when at 1200bps; V.21 at 300bps
  15. B1              Bell 212A mode when at 1200bps; Bell 103 at 300 bps
  16. C1              Normal TX carrier switching (responds OK); has no
  17.                 effect, for Hayes compatibility
  18. D               Dial number that follows D in command line 
  19. L               redial last number 
  20. P               Pulse dialing 
  21. T               Tone dialing 
  22. R               Accepted, but ignored    
  23. S7 @            Wait for silence, 5 seconds , Pause for time in S8 ; Return to command state 
  24.  
  25.  
  26.  
  27.  
  28.  
  29.  
  30.  
  31.  
  32.  
  33.  
  34.  
  35.  
  36.  
  37.  
  38.  
  39.  
  40.  
  41.  
  42.  
  43.  
  44.  
  45.                                    14
  46.  
  47. Command          Definition
  48. E1               Enable character echo to terminal in command mode
  49. F, F0            (V.32bis only) Select Line Modulation, Auto-detect mode, connect
  50.                   at highest speed. See N command, and S37 register
  51. F1               (V.32bis only) 300 Baud Carrier, either V.21 or Bell 103 set by B command
  52. F2               (V.32bis only) Reserved
  53. F3               (V.32bis only) V.23 Line Carrier, Originate = 75 Bps, Answer = 1200 Bps
  54. F4               (V.32bis only) 1200 Baud Carrier, either V.22 or Bell 212 set by B  command
  55. F5               (V.32bis only) 2400 Baud Carrier, V.22 bis
  56. F6               (V.32bis only) 4800 Baud Carrier, V.32bis or V.32 according to modem capabilities
  57. F7               (V.32bis only) 7200 Baud Carrier, V.32bis at 7200
  58. F8               (V.32bis only) 9600 Baud Carrier, V.32 or V.32bis according to  modem capabilities
  59. F9               (V.32bis only) 12000 Baud Carrier, V.32bis
  60. F10              (V.32bis only) 14400 Baud Carrier, V.32bis
  61. H0               Go on-hook (hang up)
  62. H1               Go off-hook, enter command mode, and wait for the period of time  specified by Register S7
  63. I, I0             Display product ID code
  64. I1                Returns the checksum value of ROM or an "OK" message
  65. I2                Return OK/ERROR on RAM checksum
  66. I3                Return Firmware Revision
  67. I4                Return Manufacturer's test string
  68. I5                Return Country Code
  69. I6                Return Data Pump type
  70. L, L0             Lowest speaker volume
  71. L1                Low speaker volume
  72. L2                Medium speaker volume
  73. L3                High speaker volume
  74.  
  75.  
  76.  
  77.  
  78.  
  79.  
  80.  
  81.  
  82.  
  83.  
  84.  
  85.  
  86.  
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.                               15
  94.  
  95. Command          Definition
  96. M, M0            Speaker off
  97. M1               Speaker on until carrier detect
  98. M2               Speaker always on
  99. M3               Speaker on only while answering
  100. N, N0            Connection speed set to that set in S37; if S37=0, DCE rate equals last DTE rate, or AT command
  101. N1               Connection speed set to highest possible DCE rate, Automode
  102. O, O0            Return to on-line data mode from on-line command mode
  103. O1               Go on-line and initiate retrain (2400 bps or higher)
  104. P                Pulse dialing
  105. Q, Q0            Modem returns result codes (Quiet disabled)
  106. Q1               Modem does not return result codes (Quiet enabled)
  107. Sr               Select 'r' to be the default S Register
  108. Sr=n             Set register 'r' to value 'n'
  109. Sr?              Show value in register 'r'
  110. T                Tone Dialing
  111. V, V0            Short form result codes (Verbose disabled)
  112. V1               Full-word result codes (Verbose enabled)
  113. W0               Negotiation progress codes disabled. Result code is DTE rate.
  114. W1               Negotiation progress codes enabled. \V setting is ignored. Hayes 4 line format, Carrier, Protocol, Compression, DTE *rate.
  115. W2               Negotiation progress codes disabled. Result code is DCE rate.
  116. X, X0            Smartmodem 300 compatible; CONNECT result code enabled.
  117. X1               Modem ignores dialtone and busy, CONNECT nnnn result code enabled
  118. X2               Modem ignores busy, CONNECT nnnn result code enabled.
  119. X3               Modem ignores dialtone, CONNECT nnnn result code enabled.
  120.  
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.  
  128.  
  129.  
  130.  
  131.  
  132.  
  133.  
  134.  
  135.  
  136.  
  137.  
  138.  
  139.                               16
  140.  
  141. Command          Definition
  142. X4               Modem recognizes dialtone and busy, CONNECT nnnn result code enabled.
  143. Y, Y0            Disable long-space disconnect
  144. Y1               Enable long-space disconnect
  145. Z, Z0            Reset modem and recall User Profile 0
  146. Z1               Reset modem and recall User Profile 1
  147. Z2               Reset modem and recall User Profile 2
  148.  
  149.  
  150.  
  151. &                Commands 
  152.  
  153. This table contains commands that begin with "&" as indicated.
  154.  
  155.  
  156. Command          Definition
  157. &C, &C0          Carrier always ON, DCD
  158. &C1              Carrier Detect follows data carrier
  159. &D, &D0          Modem ignores DTR
  160. &D1              Go to command mode on ON-to-Off DTR transition
  161. &D2              Hang up & go to command mode on On-to-Off DTR transition. DTR off does not allow an incoming call.
  162. &D3              Reset (ATZ) on On-to-Off DTR transition, causes modem to Hang up
  163. &D4              Deliver all buffered data before disconnecting on On-to-Off  transition of DTR, S21 = &D2, S38 = 255 (send all data)
  164. &E0              Disable auto retrain. See %E
  165. &E1              Enable auto retrain, Fall back. See %E1
  166. &E2              Enable Fall Back, Fall Forward. See %E2
  167. &F, &F0          Recall factory settings as active configuration. Error Correction  Mode, V.42bis Configuration=>MNP=>Async
  168. &F1              Recall second factory settings as active: MNP format=>Async
  169. &F2              Recall third factory settings as active, Async modem Standard                    modem with no error correction protocols.
  170. &G, &G0          No guard tones
  171. &G1              550 Hz guard tone
  172.  
  173.  
  174.  
  175.  
  176.  
  177.  
  178.  
  179.  
  180.  
  181.  
  182.  
  183.  
  184.  
  185.                               17
  186.  
  187. Command          Definition
  188.  
  189. &G2               1800 Hz guard tone
  190. &K0               Flow control is off
  191. &K3               Hardware flow control (RTS/CTS)
  192. &K4               XON/XOFF flow control
  193. &K5               Transparent XON/XOFF flow control
  194. &K6               Hardware and XON/XOFF flow control
  195. &M0               Asynchronous mode, See &Q0
  196.                   &M1, M2, M3 See &Q1, Q2, Q3 Sync mode (ignored)
  197. &N, &N0           Normal numeric result codes displayed, Hayes format
  198. &N1               Microcom QX/4232hs-compatible numeric result codes displayed
  199. &N2               Rockwell numeric result codes displayed. Also allows forced messages enabled in S95
  200. &P, &P0           Pulse dial make-break 39%/61%, 10 pulses per second.
  201. &P1               Pulse dial make-break 33%/67%, 10 pulses per second.
  202. &P2               Pulse dial make-break 39%/61%, 20 pulses per second.
  203. &P3               Pulse dial make-break 33%/67%, 20 pulses per second.
  204. &Q0               Asynchronous mode (same as &M0)
  205. &Q1               Synchronous mode 1 (ignored)
  206. &Q2               Synchronous mode 2 (ignored)
  207. &Q3               Synchronous mode 3 (ignored)
  208. &Q4               Hayes AutoSync mode
  209. &Q5               Error Correction Mode.V.42=>MNP=>Async (=> = "If previous condition fails, Fallback To")
  210. &Q6               Asynchronous Normal mode, Speed buffered
  211. &Q7               V.42bis mode =>Async fallback, see \N5 (=> = "If previous condition fails, Fallback To")
  212. &R0               CTS follow RTS with S26 delay, per V.25bis Specification
  213. &R1               CTS always on, Unless Hardware Flow Control is in effect
  214. &S0               DSR is always on
  215. &S1               DSR is FALSE until CONNECT
  216.  
  217.  
  218.  
  219.  
  220.  
  221.  
  222.  
  223.  
  224.  
  225.  
  226.  
  227.  
  228.  
  229.  
  230.  
  231.  
  232.  
  233.  
  234.                               18
  235.  
  236. Command          Definition
  237. &T, &T0          Terminate test (precede with +++)
  238. &T1              Initiate local analog loopback test (transmit and receive in low  channel)
  239. &T3              Initiate local digital loopback test
  240. &T4              Grant request from remote for remote digital loopback test
  241. &T5              Deny request from remote for remote digital loopback test
  242. &T6              Initiate remote digital loopback test
  243. &T7              Initiate remote digital loopback with self-test
  244. &T8              Initiate local analog loopback with self-test
  245. &U0              Data compression disabled. (See %C0)
  246. &U1              Data compression enabled. (See %C0)
  247. &V               View active configuration, profiles, (0,1), and numbers
  248. &W, &W0          Save active configuration as User Profile 0.
  249. &W1              Save active configuration as User Profile 1.
  250. &W2              Save active configuration as User Profile 2. (Cellular)
  251. &Y, &Y0          Recall User Profile 0 on power-up
  252. &Y1              Recall User Profile 1 on power-up
  253. &Y2              Recall User Profile 2 on power-up
  254. &Zn=x            Store phone number 'x' in directory entry 'n' (n = 0...3, x = 36 character max)
  255.  
  256.  
  257.  
  258.  
  259.  
  260.  
  261.  
  262.  
  263.  
  264.  
  265.  
  266.  
  267.  
  268.  
  269.  
  270.  
  271.  
  272.  
  273.  
  274.  
  275.  
  276.  
  277.  
  278.  
  279.  
  280.  
  281.  
  282.  
  283.  
  284.                          19
  285.  
  286. \                Commands 
  287. This table contains commands that begin with "\" as indicated.
  288.  
  289. Command          Definition
  290. \A,\A0           Maximum MNP block size = 64 characters
  291. \A1              Maximum MNP block size = 128 characters
  292. \A2              Maximum MNP block size = 192 characters
  293. \A3              Maximum MNP block size = 256 characters
  294. \Bn              Send a n*100 msec. BREAK to remote; default is 300msec. n = 0...9
  295. \G, \G0          Disable port flow control DCE to DCE
  296. \J,\J0           (V32.bis only) Disable port rate adjust. Serial port is independent of the connection. NORMAL connection.
  297. \J1               (V32.bis only) Enable port rate adjust. After a connection is made, the serial port adjusts to the rate of the connection. Same as a DIRECT connection.
  298. \G1              Enable port XON/XOFF flow control, DCE to DCE
  299.                The following \K commands have three different modes for each command:
  300.                Mode 1 = BREAK character received while modem is in data                     transfer mode
  301.                Mode 2 = Modem is in On-line command state during a data                          connection and BREAK character is received from DTE.
  302. \K,\K0               Mode 1: Enter command mode, do not transmit BREAK
  303.                Mode 2: Purge buffers and transmit BREAK
  304.                Mode 3: Purge buffers, relay BREAK to DTE
  305. \K1               Mode 1: BREAK from DTE=Purge buffers, transmit BREAK
  306.                Mode 2: BREAK Command=Purge buffers and transmit BREAK
  307.                Mode 3: BREAK from remote=Purge buffers, relay BREAK to                     DTE
  308. \K2            Mode 1: BREAK from DTE=Enter command mode, do not transmit BREAK
  309.                Mode 2: BREAK Command=Transmit BREAK immediately
  310.                Mode 3: BREAK from remote=relay BREAK to DTE immediately
  311.  
  312.  
  313.  
  314.  
  315.  
  316.  
  317.  
  318.  
  319.  
  320.  
  321.  
  322.  
  323.  
  324.  
  325.  
  326.  
  327.  
  328.  
  329.                               20
  330.  
  331. Command          Definition
  332.  
  333. \K3            Mode 1: BREAK from DTE=Transmit BREAK immediately
  334.                Mode 2: BREAK Command=Transmit BREAK immediately
  335.                Mode 3: BREAK from remote=relay BREAK to DTE immediately
  336. \K4            Mode 1: BREAK from DTE=Enter command mode, do not transmit BREAK
  337.                Mode 2: BREAK Command=Transmit BREAK in sequence with
  338.                      data
  339.                Mode 3: BREAK from remote=relay BREAK to DTE in sequence with data
  340. \K5            Mode 1: BREAK from DTE=Transmit BREAK in sequence with data
  341.                Mode 2: BREAK Command=Transmit BREAK in sequence with  data
  342.                Mode 3: BREAK from remote=relay BREAK to DTE in sequence with data
  343. \L,\L0         MNP stream link
  344. \L1            MNP block link
  345. \N,\N0         Set normal mode, no error correction, Speed buffered
  346. \N1            Set Direct mode, no error correction, No speed Buffering. DTE speed changed to DCE rate after CONNECT message. NOTE:
  347.                7200=9600 rate; 14400, 12000=19200 DTE rate
  348. \N2            Set Reliable mode (MNP only)
  349. \N3            Set Auto-reliable mode (MNP with fallback to normal)
  350. \N4            Set Reliable mode (LAPM only)
  351. \N5            Set Auto-reliable mode (LAPM fallback to normal)
  352. \N6            Set Reliable mode (LAPM with fallback to MNP)
  353. \N7            Set Auto-reliable mode (LAPM with fallback to MNP then to  normal)
  354. \Q,\Q0         Disable flow control
  355. \Q1            Bidirectional XON/XOFF flow control
  356. \Q2            Unidirectional hardware flow control
  357. \Q3            Bidirectional hardware flow control
  358. \Q4            Unidirectional XON/XOFF flow control
  359. \Q5            Unidirectional hardware flow control with CTS off until CONNECT
  360.  
  361.  
  362.  
  363.  
  364.  
  365.  
  366.  
  367.  
  368.  
  369.  
  370.  
  371.  
  372.  
  373.  
  374.  
  375.                               21
  376.  
  377. Command          Definition
  378.  
  379. \Q6               Bidirectional hardware flow control with CTS off until CONNECT
  380. \S                Display current Configuration, Long Version
  381. \Tn               Inactivity timer (0-255 minutes) default=0, disabled
  382. \V,\V0            Disable /REL connect codes
  383. \V1               Enable /REL connect codes
  384. \V2               Enable MNP or LAPM connect codes
  385. \X,\X0            XON/XOFF pass through disabled
  386. \X1               XON/XOFF pass through enabled
  387.                % Commands This table contains commands that begin with "%" as indicated.
  388.  
  389. Command          Definition
  390. %Ac               Set AUTO RELIABLE fallback character "c". Default value of "c" is 0, which disables this feature.
  391. %Bn               (V.32bis only) Maximum modem port rate, bps; n=300, 1200, 2400, 4800, 9600; 7200, 12000, 14400 with V.32bis option.
  392. %C,%C0            Data compression disabled 
  393. %C1               Data compression requested (V.42bis in LAPM, MNP5 in MNP) 
  394. %C2               V.42bis compression only 
  395. %C3               MNP % compression only 
  396. %Dn               Delay to clear the receive buffer before hang up. n=number of  seconds to wait for buffer to clear. same as S38, default=20. If S38=255, the modem will empty all data before hang up. Set to 255 by &D4.
  397. %E,%E0            Disable Auto-retrain, See &En 
  398. %E1               Enable auto-retrain, Fall back 
  399. %E2               Enable Fall Back, Fall Forward retrain
  400. %E3               Enable auto-retrain, but use fast hangup 
  401. %G0               Disable %Bn, use Fn command, %G1 enables V.32bis only 
  402. %L                Report Line Signal Level, in -DBm 
  403. %Q                Report Line Signal Quality 
  404. %R                Display all S-registers 
  405. %V                Display firmware version
  406.  
  407.  
  408.  
  409.  
  410.  
  411.  
  412.  
  413.  
  414.  
  415.  
  416.  
  417.  
  418.  
  419.  
  420.  
  421.  
  422.                               22
  423.  
  424. * Commands This table contains commands that begin with "*" as indicated.
  425.  
  426.  
  427. Command          Definition
  428.  
  429. *H0               MNP10, Link negotiation occurs at highest speed
  430. *H1               Link negotiation occurs at 1200 bps
  431. *H2               MNP10, Link negotiation occurs at 4800 bps
  432.  
  433.   - Commands This table contains commands that begin with "-" as indicated.
  434.  
  435. Command          Definition
  436. -B                MNP10, Initiate fallback to next lowest speed
  437. -C0               MNP10, Class 10 selection, synchronous
  438. -C1               MNP10, Class 10 selection, asynchronous
  439. -C2               MNP10, Class 3 selection
  440. -C3               MNP10, Class 2 selection
  441. -J0               Disable V.42 handshake detection phase
  442. -J1               Enable V.42 handshake detection phase
  443. -K0               MNP10, Disable MNP 10 extended services
  444. -K1               MNP10, Enable MNP 10 extended services
  445. -K2               MNP10, Enable MNP 10 extended services without MNP indication during answer detect phase.
  446. -Q0               MNP10, Enable fallback to 2400 Bps or 1200 Bps
  447. -Un               MNP10, Initiate fall forward to next highest speed
  448.  
  449.  
  450. AT Commands for Non-Cellular Modems 
  451.  
  452. This section gives you an alphabetic listing of AT Commands. When it is first turned on your CommuniCard modem defaults to a stored profile of settings and values (factory defined profile). You may also create four user-defined profiles to meet your individual needs and store them in the non-volatile memory.
  453.  
  454. Communication software sends an initialization string (series of AT commands) when it begins talking to the modem. This initialization string establishes a known base of modem settings for the software and modem to work with. Should it be necessary, the AT&F command is used to reset the modem to the factory default profiles.
  455.  
  456.  
  457.  
  458.  
  459.  
  460.  
  461.  
  462.  
  463.  
  464.                               23
  465.  
  466. After the factory profiles are loaded into the modem's memory and S-registers, the modem can accept commands. You may then change the parameters by changing individual commands or by recalling another user-defined profile.
  467.  
  468. Basic Modem Commands for Non-Cellular Modems This table contains an alphabetical list of basic modem commands.
  469.  
  470. Command          Definition
  471. A/                Repeat last command 
  472.  
  473. A                 Answer command \An     Block size for V.42 
  474. %An               Set autoreliable fallback character Bn     Line modulation options 
  475. &Bn               V.32 auto retrain 
  476. \Bn               Transmit break 
  477. Cn                Carrier control option 
  478. &Cn               Data carrier detect (DCD) option
  479. \Cn               Set autoreliable buffer 
  480. %Cn               Data compression 
  481. D                 Dial command 
  482. &Dn               Data terminal ready (DTR) option 
  483. En                AT command options 
  484. Fn                On-line echo command 
  485. &Fn               Load factory settings 
  486. &Gn               Guard tone option \Gn     Set serial port flow control 
  487. %Gn               Auto fall forward/fallback enable 
  488. Hn                Switch hook control 
  489. "Hn               V.42bis compression control 
  490. In                Product ID 
  491. &Jn               Dummy command for autosync
  492. \Jn               Constant DTE speed option -
  493. Jn                Set V.42 detect phase 
  494. &Kn               Select flow control 
  495. \Kn               Set break control 
  496. Ln                Speaker volume 
  497. &Ln               Dial up/leased line option 
  498. Mn                Speaker control 
  499. &Mn               Select communication mode 
  500. Nn                Select negotiate handshake
  501. \Nn               Modem protocol options 
  502. "Nn               V.42bis dictionary size 
  503. On                Go on-line
  504.  
  505.  
  506.  
  507.  
  508.  
  509.  
  510.  
  511.  
  512.  
  513.  
  514.                                   24
  515.  
  516. Command          Definition
  517.  
  518. "On               Select V.42bis Max String Length 
  519. P                 Enable pulse dialing 
  520. &Pn               Dial pulse ratio 
  521. Qn                Result code display option 
  522. &Qn               Communications mode option 
  523. \Qn               DTE flow control options 
  524. &Rn               RTS/CTS option 
  525. Sn                Selects an S register 
  526. Sn?               Read an S register 
  527. Sn=x               Write to an S register 
  528. &Sn               Data set ready (DSR) option 
  529. T                 Enable tone dialing 
  530. &Tn               Self-test commands
  531. \Tn               Set inactivity timer 
  532. &Un               Disable trellis coding 
  533. Vn                Result code form 
  534. &Vn               View active configuration/user profiles/telephone numbers
  535. \Vn               Protocol result code 
  536. -V                Display version 
  537. Wn                Select extended result code 
  538. &Wn               Store active profile Xn     Result code set/call progress 
  539. &Xn               Synch transmit clock source option
  540. \Xn               Set XON/XOFF passthrough 
  541. Yn                Dummy command 
  542. &Yn               Select stored profile on powerup 
  543. Zn                Recall stored profile 
  544. &Zn=x             Store telephone number 
  545. +FCLASS           Service class selection 
  546. +FTS              Stop transmission and pause 
  547. +FRS              Wait for silence 
  548. +FTM              Fax data transmit 
  549. +FRM              Fax data receive 
  550. +FTH              Fax HDLC frame transmit 
  551. +FRH              Fax HDLC frame receive
  552.  
  553.  
  554.  
  555.  
  556.  
  557.  
  558.  
  559.  
  560.  
  561.  
  562.  
  563.  
  564.  
  565.                                    25
  566.  
  567. AT Command Listing for Non-Cellular Modems 
  568.  
  569. This section provides descriptions of the modem command set in alphabetical order. Normally, it won't be necessary for you to change the default settings.
  570.  
  571. ALL COMMAND DEFAULTS ARE BASED ON ISSUING THE AT&F COMMAND.
  572.  
  573. Command          Definition
  574.  
  575. A/                Executes previous command without pressing ENTER. Re-executes the last command stored in the buffer. The A/ command is not preceded by "AT".
  576.  
  577. ATA               Answer immediately. Go on-line to answer, forcing the modem off hook in answer mode. The value of register S0 (number of rings the  modem is to answer on) does not affect this command. If no carrier is detected within the time specified by register S7, the modem                     hangs up.
  578.  
  579. AT\               An Sets the maximum block size during an MNP and LAPM                     connection.
  580.  
  581. This option forces the modem chipset to transmit smaller blocks of data. This command is typically used for poor quality telephone lines. When the modem transmits smaller blocks of data, it can avoid retransmissions thus improving throughput.
  582.  
  583. 0:     Max 64 characters
  584.  
  585. 1:     Max 128 characters
  586.  
  587. 2:     Max 192 characters
  588.  
  589. 3:     Max 256 characters AT%An Sets auto-reliable fallback character. Allows the user to specify the character that tells the modem to return (or fallback) from autoreliable (MNP) mode to a normal connection on the answering modem. n = 0-127 (ASCII character) Default: 013 ATBn     Communication Standard Option. This command configures the modem to the desired communications standard setting at a particular line speed.
  590.  
  591. 0:     Selects CCITT V.22 mode when the modem is at 1200 bps, and CCITT V.21 when the modem is at 300 bps.
  592.  
  593. 1:     Selects Bell 212A when the modem is at 1200 bps, and Bell 103 when the modem is at 300 bps.
  594.  
  595. 2:     Selects V.23 originate mode receive 1200 bps, transmit 75 bps; answer mode receive 75 bps, transmit 1200 bps.
  596.  
  597. 3:     Selects V.23 originate mode receive 75 bps, transmit 1200 bps; answer mode receive 1200 bps, transmit 75 bps.
  598.  
  599.                               26
  600.  
  601. Command          Definition
  602.  
  603. AT&Bn          V.32 auto retrain. Controls modem action when the threshold set by S108 is encountered.
  604.  
  605. 0:     Hang up if threshold reached.
  606.  
  607. 1:     Retrain if threshold reached.
  608.  
  609. 2:     Do not hang up and do not retrain (i.e., tolerate any line).
  610.  
  611. AT\Bn          Transmit break. This command sends a break to the remote modem. It is equivalent to using the <BREAK> key on your terminal.
  612. This command can be used if your keyboard does not have a <BREAK> key.
  613.  
  614. \B1-\B9        BREAK length in 100 ms.
  615.  
  616. Default: 0     (BREAK of 300 ms is transmitted).
  617.  
  618. ATCn Carrier control option. Used by some modems to control the transmit carrier. This chipset does not support C0 and will respond in error if this command is given. C1 ensures backward compatibility with communications software by sending the "OK" response.
  619.  
  620. 0:     Transmit carrier always off (returns ERROR).
  621. 1:     Normal transmit carrier switching.
  622.  
  623. AT&Cn Data carrier detect option (async only). Controls how the state of the DCD or RLSD (Receive Line Signal Detect) relates to the carrier from the remote modem. Always use &C1 for Sync mode.
  624.  
  625. 0:     State of carrier from remote modem is ignored. RLSD circuit is always on.
  626. 1:     State of carrier from remote modem is tracked. RLSD circuit reflects the state of carrier.
  627.  
  628. AT\Cn     Set auto-reliable buffer. Determines whether the modem chipset buffers the data it receives during link negotiation.
  629.  
  630. 0:     Does not buffer data.
  631. 1:     Buffers data on answering modem for 4 seconds, until 200 characters have been buffered, and then switches to normal mode and the buffered characters are passed to the serial port.
  632.  
  633. If a SYN character is detected, reliable mode is attempted.
  634. 2:     Does not buffer data on answering modem. Switches to normal mode upon receipt of autoreliable character and passes it to serial port.
  635. AT%Cn     Data compression. Controls the MNP Class 5. The modem can only perform data compression on an error corrected link.
  636. 0:     No compression
  637. 1:     MNP Class 5 compression.
  638.  